Abstract
OBJECTIVE: This study aimed to evaluate the use of directionality in hearing aids with wireless synchronization on localization and speech intelligibility in noise.
MATERIALS and METHODS: This study included 25 individuals with bilateral mild to moderate flat sensorineural hearing loss. For the localization experiment, eight loudspeakers (Genelec 8020B) arranged in a circle covering a 0–360° angle and the Cubase 6 software were used for presenting the stimulus. A car horn of 260 ms was presented from these loudspeakers, one at a time, randomly. The listener was instructed to point to the direction of the source. The degree of the localization error was obtained with and without directionality and wireless synchronization options. For speech perception in a noise experiment, signal to noise ratio-50 (SNR-50) was obtained using sentences played through a speaker at a fixed angle of 0°. A calibrated eight-talker speech babble was used as noise and the babble was routed either through 0°, 90°, 270° (through one speaker at a time) or through both 90° and 270° speakers.
RESULTS: The results revealed that the conditions where both the wireless synchronization and directionality were activated resulted in a significantly better performance in both localization and speech perception in noise tasks.
CONCLUSION: It can be concluded that the directionality in the wireless synchronization hearing aids coordinates with each other binaurally for better preservation of binaural cues, thus reducing the localization errors and improving speech perception in noise. The results of this study could be used to counsel and justify the selection of the directional wireless synchronization hearing aids.